Seitenansicht 0
RED-D-ARC
MX 350
IM697-B
S
eptember, 2011
Red-D-Arc Spec-Built Welding Equipment
This
RED-D-ARC
welder is built to
RED-D-ARC Extreme Duty
design specifications by Lincoln Electric.
Safety Depends on You
This welder is designed and built with safety in mind.
However, your overall safety can be increased by proper installation
... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT.
And, most importantly, think before you act and be careful.
For use with machines having Code Numbers:
10799
11149
11855
The Global Leader in Welder Rentals
OPERATOR’S MANUAL
(
Seitenansicht 0
1 2 3 4 5 6 ... 33 34

Inhaltsverzeichnis

Seite 1 - MX 350

RED-D-ARC MX 350IM697-BSeptember, 2011Red-D-Arc Spec-Built Welding EquipmentThisRED-D-ARCwelder is built to RED-D-ARC Extreme Dutydesign specifica

Seite 2 - MAGNETIC FIELDS

A-3INSTALLATION A-3• Converter welding controls are near the arc withoutlong control cables, and a receptacle is providedfor an optional rem

Seite 3 - ELECTRIC SHOCK can

BOTTOM VIEWTO ELECT.TO ELECT.TO WORKTO POWERSOURCETO POWERSOURCE+INPUT+ELECTRODEELECT.+ELECT.++IN+INA-4INSTALLATION A-4REMOTE OUTPUT CONTROL OPTIONS

Seite 4

A-5INSTALLATION A-5To connect the "pig-tail" cables to the Converter:1. Stand the Converter vertically on its rear handleand skid

Seite 5 - REDRESSEUR

A-6INSTALLATION A-6INTER-CONNECTION OF CONVERTERSThe input and electrode cables of the RED-D-ARCMX350 Converters may be inter-connected in a

Seite 6 - T h a n k

A-7INSTALLATION A-7RED-D-ARC MX350Table .1 Converters Cable Size

Seite 7 - TABLE OF CONTENTS

B-1OPERATIONB-1FRONT PANEL CONTROLSThese few instruments are basic to the operation andmonitoring of the Converter. They are intuitively laidou

Seite 8 - ELECTRICALSPECIFICATIONS

B-2OPERATIONB-2 Average Amps for about 7 seconds after weldingstops in CC and CV modes only. • The 5 second memory display is indicat

Seite 9

STORAGEThe RED-D-ARC MX350 may be set on a floor, orshelf, horizontally on its skid, or vertically standing onits rear top and bottom handles

Seite 10 - DISTRIBUTION BOX

B-4OPERATIONB-4OVER-CURRENT PROTECTIONThe max. output current of the RED-D-ARC MX350 iselectronically limited, to protect internal power compo-nents,

Seite 11 - INSTALLATION

D-1MAINTENANCED-13. Holding the unit by the front handles, so the back isfacing down, shake the loose debris out of the unit.Raking out the heatsink

Seite 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be

Seite 13 - Figure 2

D-2MAINTENANCED-2SERVICEThe RED-D-ARC MX350 was designed for easy ser-vice using quick to replace components, and assem-bly modules which

Seite 14

E-1TROUBLESHOOTINGE-1If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact

Seite 15 - Figure 3

E-2TROUBLESHOOTINGE-2Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Seite 16 - OPERATION

E-3TROUBLESHOOTINGE-3Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Seite 17

E-4TROUBLESHOOTINGE-4Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Seite 18 - OVER-CURRENT PROTECTION

E-5TROUBLESHOOTINGE-5Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedures or

Seite 19 - MAINTENANCE

F-1DIAGRAMSF-1RED-D-ARC MX350

Seite 20 - Figure 5

F-2DIAGRAMSF-2RED-D-ARC MX350

Seite 21 - TROUBLESHOOTING

F-3DIAGRAMSF-3A11 3 21DIMENSION PRINT - MX350 CONVERTERRED-D-ARC MX350

Seite 22

F-4DIAGRAMSF-4DIMENSION PRINT FOR DISTRIBUTION BOXM19448C-UFRED-D-ARC MX350

Seite 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the ar

Seite 24

NOTES RED-D-ARC MX350

Seite 25

NOTES RED-D-ARC MX350

Seite 26 - DIAGRAMS

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Seite 27

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Seite 28

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB 

Seite 29

iiiSAFETYiiiFOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b.

Seite 30 - NOTES

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPourvotre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui

Seite 31

vvT h a n kfor selecting one of our QUALITY products. We want you to takepride in operating this product ••• as much pride as we have inbr

Seite 32

vi TABLE OF CONTENTS

Seite 33

A-1INSTALLATION RED-D-ARC MX350A-1TECHNICAL SPECIFICATIONS - RED-D-ARC MX350 (K1823-1)PHYSICAL DIMENSIONSTEMPERATURE RANGESHEIGHT11.6 in295 mmWIDTH1

Seite 34

A-2INSTALLATION A-2PRODUCTDESCRIPTIONThe RED-D-ARC MX350 converter (K1823-1) is partof a Multi-Weld system, ideally suited for constructionsi