ECS System
24 I/O Drag-N-Drop DSP with AEC
ECS
AUDIO INPUTS
Audio input impedance:
10 kOhms (balanced, screw terminal).
Input sensitivity: 0 dB, -12dB, -24 dB,-40dB,
-55 dB (software selection).
Max input: +15 dBu.
Bandwidth: 20 Hz to 20 kHz.
Phantom power soft config 48 VDC.
AUDIO OUTPUTS
Audio output impedance: 100 Ohms
(balanced, screw terminal).
Max output +15 dBu.
Bandwidth 20 Hz to 20 kHz.
Total Harmonic Distortion < 0.03% , +0 dBu,
20~20 kHz, unity gain, 20 kHz BW.
S/N: (100 dB),( re+15 dBu), unity gain, 22 kHz BW.
S/N:(80 dB),( re+15 dBu),( 54 dB gain), 22 kHz BW.
Dynamic range: (100 dB),( re+15 dBu), 22 kHz BW.
SERIAL CONNECTIONS
RS232 port: for ATEÏS or third party equipment
remote control.
RS485 port: for Remote data control.
RJ45 port: for PC control and system set up
using ATEÏS-STUDIO software.
DIGITAL LINK
One RJ45 TX to send data and audio to next device.
One RJ45 Rx to receive data and audio
from the previous device.
CONTROL I/O
8 Control inputs either analog or Logical (contacts).
2 logic outputs (Dry contacts).