RBS3202 Test with CMU300 and RNC/Iub SIM
1CM56_E 12 Rohde & Schwarz
• Set the starting output level to –70 dBm (Generator Level / Total
Transmit Power: -70 dBm)
• Set the UL frequency or channel number to be used on the RNC
simulator (Generator Settings / Channel or Frequency). Note: In
normal conditions the UMTS UL frequency is 190 MHz below the
DL frequency.
• Set the UL scrambling code to be used by the RNC simulator
(Channel Settings / Dedicated Channel / Scrambling Code).
Default value for the RNC simulator: 100 hex
• Set the required offset of 1024 chips between DL and UL (Channel
Settings / Dedicated Channel / CPICH – UL DPCH Offset: 1024
Chips).
• Check whether the 3GPP reference measurement channel is set at
12.2 kbps incl. PN9.
• Set the TFCI Bits to 1100000000. (Channel Settings / 3GPP
Reference Channel / TFCI Bits: 1100000000)
• Close the Generator Configuration menu and start the generator (press
the Generator softkey on the right of the screen and the ON / OFF
hardkey). The message "Waiting for Synchronisation" should appear
and then disappear when the TTI trigger occurs. The TTI trigger is
made available on the BTS relatively infrequently (approx. 1 to 2 times
per minute).
• Check whether the BER test is currently operating correctly. For this to
be the case, all error rates on the BER analyzer must be 0% and
incoming bits must be present.
• Carry out receiver measurements by reducing the output level in
accordance with the values mentioned in [1] (softkey Total TX Power).