RBS3202 Test with CMU300 and RNC/Iub SIM
1CM56_E 5 Rohde & Schwarz
4 Test Setup
Please create the test setup according to the following block diagrams.
Transmitter measurements:
The input RF 1 to the R&S CMU300 is directly connected to the transmitter
output. Continuous power of 47 dBm RMS (54 dBm PEP) is possible on
this input. Externally applied attenuator pads can be considered in the R&S
CMU300 when configuring the RF paths. We strongly recommend that you
deactivate any DC excitation voltages that may be hooked up to RF lines.
Ericsson
RBS 3202
R&S CMU300
NetHawk
RNC/Iub
simulator incl.
N2 adapter
RF 1 input
(N female)
RF output
of cell to be
measured
(9/16 female)
NetHawk
ACSU
input REF IN
rear panel,
BNC female
E1 I ub interface
Out 2
SMA female
RJ45 Iub control cable
10 MHz reference frequency cable
RF cable (down link)
Receiver measurements:
Ericsson
RBS 3202
R&S CMU300
NetHawk
RNC/Iub
simulator incl.
N2 adapter
RF 1 ouput
(N female)
RF input
of cell to be
measured
(9/16 female)
NetHawk
ACSU
input REF IN
rear panel,
BNC female
TTI clock input
AUX3 pin 6
Sub-D-15 female
TTI clock output
"C" on TU board
SMA female
E1 Iub interface
Out 2
SMA female
RJ45 Iub control cable
10 MHz reference frequency cable
RF cable (up link)
Trigger cable
Note: If the BTS uses remote amplifiers (tower-mounted), these must be
taken into consideration in the test setup, that is, the R&S CMU300 must
be directly connected to the RF connectors on the amplifier.